Heidenhain TNC 620 (34056x-04) Cycle programming Instrukcja Użytkownika Strona 342

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 468
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 341
Touch Probe Cycles: Automatic Datum Setting
15.10 DATUM CIRCLE CENTER (Cycle 416, DIN/ISO: G416, software
option 17)
15
342
TNC 620 | User's Manual Cycle Programming | 5/2013
Probe TS axis: Coord. 3rd axis Q384 (absolute):
Coordinate of the probe point in the touch probe
axis, at which point the datum is to be set in the
touch probe axis. Only effective if Q381 = 1. Input
range -99999.9999 to 99999.9999
New datum in TS axis Q333 (absolute): Coordinate
in the touch probe axis at which the TNC should
set the datum. Default setting = 0. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to SET_UP (touch probe table), and
is only effective when the datum is probed in the
touch probe axis. Input range 0 to 99999.9999
Przeglądanie stron 341
1 2 ... 337 338 339 340 341 342 343 344 345 346 347 ... 467 468

Komentarze do niniejszej Instrukcji

Brak uwag